L-shaped aluminium profile 40x40x20 – 6mm slot

8-AS-6-404020

New

L-shaped aluminium profile 40x40x20 – 6mm slot

More details

17,64 € tax excl.

21,17 € tax incl.


Min. 50 - Max. 4000
Min price :5.3 € HT

L-shaped aluminium profile 40x40x20 – 6mm slot

    Second moment of inertia (x10^4 mm^4) (x axis)6.61
    Second moment of inertia (x10^4 mm^4) (y axis)6.61
    Linear mass density (kg/m)1.16
    Cross section (mm²)429
    Cross section (mm)40x40x20
    Number of slots8
    Size of slot6
    FinishTransparent grey anodised
    Compatibility Ø central hole4,2 mm
    MaterialEN AC-51400-T5
ImageReferenceNomUnit PriceAdd to cart
Cover profile - 6 mm slot - black CF-6-TPM-Noir 2,50 € Add
Cover profile - 6 mm slot - grey CF-6-TPM-Gris 2,50 € Add


Results are provided on an indicative basis only; Systéal accepts no liability regarding the use of this module.

Please note: this simulator currently only works for aluminium profiles. Do not use it for other materials or for panels.

Stage 1: Enter details

Load Pin kgDistance a in mm
Length L in mmLength m in mm
Young's modulusN/mm²


Stage 2: Calculate results (do not forget to update the result after changing any values)



Stage 3: Determine your setup and its maximum load



The maximum recommended load is the load that corresponds to the maximum deflection recommended by the manufacturer (1/1000th of the length of the beam)
in mm


How do I read the results?:

This setup is not recommended as the deflection is too high. Reduce the load or improve the setup.
The deflection is lower than the maximum recommended load. Your setup is OK.


Setup 1
in mm
in mm
in kg
in kg
Setup 2
in mm
in mm
in kg
in kg
Setup 3
in mm
in mm
in kg
in kg
Setup 4
in mm
in mm
in kg
in kg
Setup 5
in mm
in mm
in kg
in kg
Setup 6
in mm
in mm
in kg
in kg
Setup 7
in mm
in mm
in kg
in kg
Setup 8
in mm
in mm
in kg
in kg
Setup 9
in mm
in mm
in kg
in kg

Results are provided on an indicative basis only; Systéal accepts no liability regarding the use of this module.

Please note: this simulator currently only works for aluminium profiles. Do not use it for other materials or for panels.

Stage 1: Enter details

Load Pin kgLength L in mm
Young's modulusN/mm²


Stage 2: Calculate results (do not forget to update the result after changing any values)



Stage 3: Determine your setup and its maximum load



La charge critique de flambage (=charge maxi) est calculée avec la formule d'Euler. More information here.

How do I read the results?:

votre montage est déconseillé car la charge critique de flambage est dépassée. Réduisez la charge ou bien améliorez votre montage.
la charge critique n'est pas dépassée. Votre montage est correct.


Montage 1 : pour une poutre rotulée aux deux bouts
in kg
Montage 2 : pour une poutre encastrée - encastrée mobile (selon l'axe vertical)
in kg
Montage 3 : pour une poutre encastrée-rotulée
in kg
Montage 4 : pour une poutre encastrée-libre
in kg