Aluminium profile 25x50 6mm slot

6-AS-6-2550

New

21,00 € tax excl.

25,20 € tax incl.


Min. 50 - Max. 4000
Min price :6.3 € HT

Rectangular aluminium profile six 6mm side slots 25x50mm cross section

    Second moment of inertia (x10^4 mm^4) (x axis)2.97
    Second moment of inertia (x10^4 mm^4) (y axis)12.74
    Linear mass density (kg/m)1.36
    Cross section (mm²)503
    Cross section (mm)25x50
    Number of slots6
    Size of slot6
    FinishTransparent grey anodised
    Compatibility Ø central hole6,8 mm
    MaterialEN AC-51400-T5
ImageReferenceNomUnit PriceAdd to cart
Cover profile - 6 mm slot - black CF-6-TPM-Noir 2,50 € Add
Cover profile - 6 mm slot - grey CF-6-TPM-Gris 2,50 € Add


Results are provided on an indicative basis only; Systéal accepts no liability regarding the use of this module.

Please note: this simulator currently only works for aluminium profiles. Do not use it for other materials or for panels.

Stage 1: Enter details

Load Pin kgDistance a in mm
Length L in mmLength m in mm
Young's modulusN/mm²


Stage 2: Calculate results (do not forget to update the result after changing any values)



Stage 3: Determine your setup and its maximum load



The maximum recommended load is the load that corresponds to the maximum deflection recommended by the manufacturer (1/1000th of the length of the beam)
in mm


How do I read the results?:

This setup is not recommended as the deflection is too high. Reduce the load or improve the setup.
The deflection is lower than the maximum recommended load. Your setup is OK.


Setup 1
in mm
in mm
in kg
in kg
Setup 2
in mm
in mm
in kg
in kg
Setup 3
in mm
in mm
in kg
in kg
Setup 4
in mm
in mm
in kg
in kg
Setup 5
in mm
in mm
in kg
in kg
Setup 6
in mm
in mm
in kg
in kg
Setup 7
in mm
in mm
in kg
in kg
Setup 8
in mm
in mm
in kg
in kg
Setup 9
in mm
in mm
in kg
in kg

Results are provided on an indicative basis only; Systéal accepts no liability regarding the use of this module.

Please note: this simulator currently only works for aluminium profiles. Do not use it for other materials or for panels.

Stage 1: Enter details

Load Pin kgLength L in mm
Young's modulusN/mm²


Stage 2: Calculate results (do not forget to update the result after changing any values)



Stage 3: Determine your setup and its maximum load



The critical buckling load (=maximum load) is calculated using Euler's formula. More information here.

How do I read the results?:

This setup is not recommended as the critical buckling load has been exceeded. Reduce the load or improve the setup.
You have not exceeded the critical load. Your setup is OK.


Setup 1: for a beam that is pinned at both ends
in kg
Setup 2: for a fixed-fixed beam (mobile along the vertical axis)
in kg
Setup 3: for a fixed-pinned beam
in kg
Setup 4: for a fixed-free beam
in kg